Industrial High-Volume Air Purifier

Send forespørgsel
Industrial High-Volume Air Purifier
Detaljer
Heavy-duty industrial air filtration system engineered for high-volume particulate removal in heavy manufacturing, welding facilities, and large workshops. Built with heavy-gauge carbon steel housing and continuous-duty blowers to handle continuous multi-shift operation. Designed to maintain OSHA-compliant indoor air quality and protect plant infrastructure from heavy dust loading and aerosol accumulation. Direct factory manufacturer supplying OEM/ODM configurations and bulk plant installations.
Produkt klassificering
Share to
Beskrivelse

Heavy-duty industrial air filtration system engineered for high-volume particulate removal in heavy manufacturing, welding facilities, and large workshops. Built with heavy-gauge carbon steel housing and continuous-duty blowers to handle continuous multi-shift operation. Designed to maintain OSHA-compliant indoor air quality and protect plant infrastructure from heavy dust loading and aerosol accumulation. Direct factory manufacturer supplying OEM/ODM configurations and bulk plant installations.

 

 

 

Multi-Stage Filtration Architecture: Houses configurable pre-filters, MERV 15 bag filters, and HEPA or activated carbon modules for broad-spectrum pollutant capture.

 

Continuous-Duty Direct-Drive Blower: High-static-pressure centrifugal fan optimized for extended pressure drops across loaded filter media.

 

Integrated Magnehelic gauges track real-time pressure drop across each filter stage to signal exact replacement intervals.

 

Heavy-Gauge Structural Integrity: 2.0mm cold-rolled steel cabinet finished with industrial-grade powder coating to resist corrosion in harsh production environments.

 

Tool-free hinged side panels allow rapid filter extraction, minimizing maintenance downtime during shift changes.

 

In-House Manufacturing & QA: Fabricated via CNC laser cutting, robotic welding, and dynamic rotor balancing on-site, ensuring strict dimensional and operational consistency.

 

 

 

2,000 CFM – 10,000 CFM (Model dependent)

Up to 99.97% at 0.3 microns (HEPA configuration)

3.0 kW – 15 kW (3-Phase, 380V/480V, 50Hz/60Hz)

Up to 2,500 Pa

2.0mm Cold-Rolled Carbon Steel / Optional 304 Stainless Steel

68 dB(A) – 78 dB(A) at 1 meter

PLC-controlled digital touch panel / VFD speed regulation

CE, ISO 9001:2015, UL-listed electrical components available

 

 

 

Captures hexavalent chromium, metal fumes, and coarse grinding sparks at source or ambient level.

 

Removes fine sanding dust, priming aerosols, and particulate debris prior to finishing zones.

 

Handles high-volume wood dust, MDF particles, and fibrous debris via ducted network integration.

 

Contains dry bulk powders, pharmaceutical dust, and granular airborne contaminants.

 

 

 

Customized inlet/outlet duct diameters, multi-port manifold connections, or direct ambient discharge louvers.

 

Specific media selection including high-capacity oil mist coalescers, spark arrestors, or impregnated carbon for VOC adsorption.

 

Voltage customization (220V to 575V), explosion-proof motor options (ATEX / Class I Div 2), and remote BMS (Building Management System) integration.

 

Food-grade stainless steel fabrication or specialized anti-corrosion marine coatings for humid or corrosive facility environments.

 

 

 

Fabricated using Trumpf CNC fiber laser cutting and CNC press brake bending for precise structural tolerances.

 

Structural joints executed via robotic MIG welding by AWS/ISO-certified welding operators.

 

Every blower wheel undergoes dynamic balancing on computerized balancing rigs to ISO 1940 G2.5 standards, limiting vibration and bearing wear.

 

Each unit undergoes a 4-hour full-load electrical draw test, dielectric strength testing, and airflow performance verification prior to crating.

 

 

 

Q: What is the filter replacement frequency under multi-shift operation?

A: Pre-filters typically require inspection monthly and replacement every 3 to 6 months. HEPA or secondary bag filters last 12 to 24 months depending on dust loading density, monitored via differential pressure gauges.

A: Yes. Inlet and discharge collars are customizable in round or rectangular formats to match standard spiral ducting and local exhaust ventilation (LEV) systems.

A: Main control panels utilize IEC/UL-certified components. Motors are TEFC (Totally Enclosed Fan Cooled) rated with IP55 or IP56 protection classes.

A: Standard catalog configurations ship within 15 to 25 business days. Custom engineering, specialized voltage, or stainless steel builds require 35 to 45 business days.

A: Units are secured to fumigated wooden skids, wrapped in heavy-duty moisture-barrier VCI film, and enclosed in robust export-grade plywood crates to prevent transit corrosion or shock damage.

A: Each delivery includes an installation manual, wiring schematics, PLC programming logic sheets, individual FAT test reports, and ISO 9001 quality certificates.

 

 

 






Download 2D/3D CAD Package|Submit RFQ / Contact Technical Sales Team

 

Populære tags: industrial high-volume air purifier, China industrial high-volume air purifier manufacturers, suppliers, factory

Send forespørgsel